Table of Contents Table of Contents
Previous Page  27 / 36 Next Page
Information
Show Menu
Previous Page 27 / 36 Next Page
Page Background

Italy: Autogrill Villoresi Est

http://www.autogrillvilloresiest.it/en

Autogrill Villoresi Est is an example of Italian restaurant strongly engaged in energy efficiency. The service

area embodies a number of innovative, expert solutions that optimize energy consumption and resource

use while safeguarding nature and the environment. These are based on the international best practices

for environmental protection. Villoresi Est is made of eco-friendly, recyclable building materials, and the

entire skeleton of the building is constructed of PEFC-certified glued laminate timber from sustainable

forests. The building is constructed of eco-friendly, recyclable materials. Villoresi Est features numerous

technological innovations including a solar roof that harvests energy from the sun and a closed-circuit

geothermal plant whose 25-meter-deep geothermal probes can supply 380 kilowatts of geothermal

energy. The building is equipped with a system to collect and recycle rainwater and groundwater, which

are used in the air conditioning, green irrigation, toilets and fire protection system.

Spain: HIPOTELS Bahía Cala Millor Hotel (Mallorca)

www.hipotels.com

The reform consists of the conversion of an apartment building

with 30 years of antiquity into a 4* hotel. A dining room for clients,

a cooking show and a central kitchen are added. Reorganize

noble areas and delete the apartments on the ground floor

and basement to the new spaces. The envelope of the building

is sought by replacing windows and covering cone partition

walls Insulation around the exterior perimeter, achieving energy

certification level B.

The addition of the thermal envelope suggests that will lead to

a decrease in losses of 25% by heat transmission of the exterior

facades. Of the same way the losses by windows and large

windows they will be reduced by 35%. The combination of both

measures implies a reduction 28.30% of the thermal losses due

to the envelope of the building. Heat recovery from boiler fumes

provide us with a 9% reduction in the cost of fuel, going from

96% to 105% over PCI, using energy according to its quality, there

where is able to provide the highest performance.

The high temperature heat recovery of the refrigerating machines allows reaching a reduction 15% in fuel

expense being indicated for heating ACS and any other use that requires high quality of energy. The solar

panels allow a 20% annual reduction in consumption of energy, since its use is not only for production of ACS

but it is distributed where it is needs according to the level of energy produced.

Making tourism more resource efficient: guidance and solutions to raise energy efficiency in the european hospitality industry

|

27